Controllers
Reactive Power Compensation Controller
The Reactive Power Compensation Controller is a fully digital device with AC sampling and a large-screen LCD Chinese interface. It displays real-time power factor, voltage, current, active power, reactive power, voltage and current THD, frequency, capacitor output and switching status, and alarms for L1, L2, and L3.

Overview
The controller uses reactive power as the sampling quantity and includes harmonic measurement and protection. Capacitor control schemes support three-phase compensation, split-phase compensation, and combined compensation, selectable via menu. Switching control programs support equal-capacity, coding, and fuzzy control modes, with manual and automatic operation. An RS-485 MODBUS fieldbus interface allows connection to intelligent switchgear systems. Optional factory power distribution monitoring software can be connected to the controller communication port to view real-time data, historical load curves, and reports on a computer. Data can be uploaded to a cloud platform for remote monitoring.
Key features
- Fully digital design with AC sampling
- Large-screen LCD Chinese interface
- Real-time display of L1, L2, L3 power factor, voltage, current, active power, reactive power, voltage THD, current THD, frequency, capacitor output and switching status, and alarms
- Menu-based setting of control schemes
- Three-phase compensation, split-phase compensation, and combined compensation
- Equal-capacity, coding, and fuzzy control switching modes
- Manual and automatic compensation modes
- Reactive power sampling with harmonic measurement and protection
- RS-485 MODBUS fieldbus communication interface
- Optional factory power distribution monitoring software
- Data upload to cloud platform for remote monitoring
- Thyristor control mode
Technical information
- Current variation
- 1 ~ 1200 (ratio value)
- Delay time
- 0.1s ~ 30s (dynamic)
- Target power factor
- lagging 0.90 ~ leading 1.00, step 0.01
- Overvoltage setting
- 230V ~ 290V
- Undervoltage setting
- 180V ~ 200V, or off
- Harmonic protection
- Hv: 1.0% ~ 50% (0.0% disables this protection); Hi: 2% ~ 100% (0.0% disables this protection)
- Split-phase compensation capacitor bank setting
- 0 ~ 4 (number of banks per phase)
- Three-phase compensation capacitor bank setting
- 0 ~ 12
- Capacitor bank allocation
- split-phase banks × 3 + three-phase banks ≤ 12
- Capacitor preset
- 0 ~ 999kvar
- Voltage measurement accuracy
- ±0.5%
- Current measurement accuracy
- ±1.0%
- Power factor measurement accuracy
- ±1.0%
- Active power measurement accuracy
- ±0.5%
- Reactive power measurement accuracy
- ±1.0%
- Frequency measurement accuracy
- ±0.1Hz
- Measured voltage
- 100V~290V
- Measured current
- 0~6000A
- Sensitivity
- 50mA
- Measured power factor
- lagging 0.200~leading 0.200
- Operating power supply
- 220V±20%
- Measured frequency
- 47~53Hz
- Active power display
- 0~6553kw
- Reactive power display
- 0~6553kvar
- Voltage THD display
- 0.0~100.0%
- Current THD display
- 0.0~100.0%
- AZSD12
- Control voltage DC12V, 12 outputs
- AZSD18
- Control voltage DC12V, 18 outputs, customizable
- AZSD24
- Control voltage DC12V, 24 outputs, customizable
Ratings shown relate to the pictured sample. Final ratings are confirmed against your order.